Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses

2011

PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…

AdultCorneal Wavefront AberrationDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityArtificial Lens Implant MigrationRefraction OcularYoung AdultPostoperative ComplicationsHumansMedicineContrast (vision)media_commonLenses Intraocularbusiness.industryLASIKeye diseasesOphthalmologySpherical aberrationHyperopiaTilt (optics)Intraocular lensesDecreased Visual AcuityOftalmologíaOptometryLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.

2014

Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …

AdultDepth of focusPhakic Intraocular LensesVisual acuityCorneal Wavefront Aberrationgenetic structuresVisual AcuityDiagnostic Techniques OphthalmologicalPhakic intraocular lensProsthesis DesignYoung AdultLens Implantation IntraocularmedicineHumansComputer SimulationAdaptive opticsDioptreMathematicsWavefrontDepth PerceptionPupilPresbyopiaPresbyopiamedicine.diseaseeye diseasesSensory SystemsOphthalmologySpherical aberrationOptometrySurgerysense organsmedicine.symptomJournal of cataract and refractive surgery
researchProduct

Medium-term visual, refractive, and intraocular stability after implantation of a posterior chamber phakic intraocular lens to correct moderate to hi…

2011

To evaluate the medium-term refractive and visual outcomes and the complications after implantation of a silicone posterior chamber phakic intraocular lens (PC pIOL) for moderate to high myopia.Oftalmar, Medimar International Hospital, Alicante, Spain.Retrospective case series.Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, and intraocular pressure were evaluated during a medium-term follow-up. Postoperative complications were also studied.The study enrolled 35 eyes (mean preoperative spherical equivalent [SE] -10.25 diopters [D] ± 3.19 [SD]) of 20 patients with a mean age of 31.83 ± 8.87 years and a mean follow-up of 57.34 ± 9.24 months. The mean UDVA improved…

AdultMaleIntraocular pressuremedicine.medical_specialtyPhakic Intraocular LensesVisual acuitygenetic structuresVisual AcuityPhakic intraocular lensRefraction OcularMedium termYoung AdultPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMedicineHumansDioptreIntraocular PressureRetrospective Studiesbusiness.industryHigh myopiaPosterior Eye SegmentMiddle AgedRefractioneye diseasesSensory SystemsPosterior chamber phakic intraocular lensOphthalmologyTreatment OutcomeMyopia DegenerativeSurgeryFemalemedicine.symptombusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Visual quality comparison of conventional and Hole-Visian implantable collamer lens at different degrees of decentering

2013

Purpose To compare the visual quality of implantable collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering. Methods An adaptive optics visual simulator (crx1, Imagine Eyes, Orsay, France) was used to simulate the –3, –6 and –12 dioptres (D) conventional and Hole ICLs in three conditions: centred and decentred 0.3 and 0.6 mm. Visual acuity (VA) at high-contrast, medium-contrast and low-contrast and contrast sensitivity (CS) were measured in 15 observers for 3 and 4.5 mm pupils. Results No statistically significant differences in VA and CS were found between conventional and Hole ICLs for any ICL powers and pupil sizes evaluated …

AdultMaleOptics and PhotonicsPhakic Intraocular LensesVisual acuitymedia_common.quotation_subjectVisual AcuityPupilContrast SensitivityYoung AdultCellular and Molecular NeuroscienceQuality (physics)Lens Implantation IntraocularMyopiamedicineHumansContrast (vision)media_commonImplantable collamer lensbusiness.industryAberrometrySensory SystemsOphthalmologyOptometryFemalemedicine.symptombusinessBritish Journal of Ophthalmology
researchProduct

Optical and Visual Simulation of Standard and Modified Spherical Aberration Implantable Collamer Lens Post Myopic LASIK Surgery

2013

To evaluate the visual quality achieved in patients undergoing standard or modified implantable Collamer lens (ICL) to correct residual myopic error after laser-assisted in situ keratomileusis (LASIK) surgery.The adaptive optics visual simulator was used to simulate LASIK surgery of moderate and high myopia with a myopic regression corrected by a standard and modified ICL. Visual acuity (VA) and contrast sensitivity (CS) were measured in 14 subjects at 3- and 4.5-mm pupil. Point spread function and simulated retinal images were calculated.Comparing LASIK plus standard ICL and LASIK plus modified ICL simulations, for moderate myopia, VA improvement was less than 1 line in all VA contrasts an…

AdultMaleOptics and PhotonicsPhakic Intraocular Lensesmedicine.medical_specialtyCorneal Wavefront AberrationAdolescentgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisPhakic intraocular lensContrast SensitivityYoung AdultLens Implantation IntraocularAberrometryMyopiamedicineHumansIn patientPostoperative PeriodImplantable collamer lensbusiness.industryAberrometryLASIKGeneral Medicineeye diseasesSurgeryOphthalmologySpherical aberrationOptometryFemaleLasers ExcimerbusinessEuropean Journal of Ophthalmology
researchProduct

Five-year functional outcomes and vault of -20 diopter myopic phakic intraocular lens implantation.

2015

Purpose To evaluate refractive and visual outcomes and complications associated with phakic intraocular lens (pIOL) implantation to correct high myopia. Settings Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective observational case series. Methods Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, vault, and adverse effects were evaluated after 5 years with Visian ICMV4 pIOL. Results Mean spherical equivalent (SE) dropped from −18.32 ± 2.37 diopters (D) preoperatively to −0.88 ± 0.52D 5 years postoperatively; 61% of eyes were within ±0.75 D of the target. The mean Snellen decimal CDVA and UDVA were 0.73 ± 0.23 and 0…

AdultMalePhakic Intraocular LensesVisual acuityAnterior subcapsular cataractDistance visual acuityBiometrygenetic structuresmedicine.medical_treatmentVisual AcuityPhakic intraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularAnterior Eye SegmentmedicineMyopiaHumansDioptreRetrospective StudiesEfficacy indexbusiness.industryHigh myopiaCataract surgeryeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessTomography Optical CoherenceFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism

2015

Purpose To evaluate the prevalence of cataract after Implantable Collamer Lens phakic intraocular lens (pIOL) implantation with different models at different ages and for different refractive powers. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective nonrandomized clinical study. Methods The pIOL (models V4, V4b, or V4c) was implanted in all cases. Results The study included 3420 eyes (1898 patients). The mean patient age at surgery was 31.2 years ± 6.4 (SD) (range 18 to 50 years) and the mean spherical refractive error, −7.27 ± 5.24 diopters (D) (range −26.5 to 12.5 D). Twenty-one eyes (0.61%) of 15 patients had pIOL explantation (all model V4) because c…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyAdolescentgenetic structuresPolymersmedicine.medical_treatmentVisual AcuityAstigmatismMyopia/hyperopiaPhakic intraocular lensCataractLens Implantation IntraocularCataractsOlder patientsPatient ageOphthalmologyMyopiaPrevalencemedicineHumansDevice RemovalDioptreRetrospective Studiesbusiness.industryAstigmatismMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaSpainFemaleSurgeryCollagensense organsbusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Collagen copolymer posterior chamber phakic intraocular lens supported by the ciliary sulcus to treat myopia: One-year follow-up

2014

Purpose To evaluate the predictability, stability, safety, and efficacy of Visian V4b Implantable Collamer Lens phakic intraocular lens (pIOL) implantation to treat varying degrees of myopia. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, and adverse effects were evaluated 12 months postoperatively. Results The study enrolled 121 eyes (68 patients). The mean spherical equivalent decreased from −8.61 diopters (D) ± 3.41 (SD) (range −18.75 to −2.25 D) preoperatively to −0.18 ± 0.29 D (range −1.25 to 0.50 D) 12 months postoper…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyCiliary sulcusgenetic structuresOne year follow upPolymersVisual AcuityBiocompatible MaterialsPhakic intraocular lensYoung AdultLens Implantation IntraocularOphthalmologyMyopiamedicineHumansProspective StudiesIntraoperative ComplicationsProspective cohort studyDioptreImplantable collamer lensEfficacy indexbusiness.industryCiliary Bodyeye diseasesSensory SystemsPosterior chamber phakic intraocular lensOphthalmologyFemaleSurgeryCollagenbusinessJournal of Cataract and Refractive Surgery
researchProduct

Clinical Impact of a Spontaneous Decentration of a Phakic Refractive Lens

2011

PURPOSE To evaluate the clinical impact and possible causes of a spontaneous decentration of a phakic refractive lens (PRL) implanted in a highly myopic eye, and analyzing the visual, refractive, and aberrometric outcome as well as the possible causes for this phenomenon. METHODS The description of a case of bilateral high myopia corrected by implantation with the phakic intraocular lens (pIOL) PRL (Carl Zeiss Meditec, Germany) is presented and documented. Both eyes had similar anatomical configuration, and therefore, a pIOL (Model 101) with the same size was implanted without any associated intraoperative complication. Clinical outcomes were evaluated during a 3-month follow-up. RESULTS Im…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyDistance visual acuitygenetic structuresVisual AcuityComa (optics)Anatomical configurationRefraction OcularPhakic intraocular lensPostoperative ComplicationsOphthalmologyAberrometryMyopiamedicineHumansbusiness.industryLens SubluxationRefractive lensSubjective refractioneye diseasesOphthalmologySpherical aberrationsense organsbusinessFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation

2009

PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyRefractive errorBiometryAdolescentgenetic structuresEye diseasePhakic intraocular lensVision disorderYoung Adult03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansBody Weights and MeasuresImplantable collamer lensScience & Technologybusiness.industryOutcome measuresMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudiesVault (architecture)Implantable Contact Lens030221 ophthalmology & optometryOptometryFemalesense organsmedicine.symptombusinessTomography Optical Coherence030217 neurology & neurosurgeryAmerican Journal of Ophthalmology